Abstract
This paper describes an on-machine measurement function of a micro electro-discharge machine (µ-EDM) to evaluate the quality of micro ball-ended stylus tips fabricated by a combination of wire-electro-discharge grinding (WEDG) and one-pulse-electro-discharge (OPED) technology. A low-voltage contacting trigger function without any capacitor between a stationary wire and the spindle of a µ-EDM was used to measure the outer profile and evaluate the forming quality. The measurement results show that the deviation of the largest radius between the micro ball-ended tip and stem is approximately 3 µm. Moreover, OPED/WEDG is also easily able to produce high-quality micro spherical stylus tips with a standard deviation as small as 0.7 µm through use of sharp-needle-shaped electrode tools. With further improvements in electro-discharge position, OPED and WEDG technology are promising and excellent approaches for manufacturing micro coordinate measurement machine (CMM) spherical stylus tips.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.