Abstract

A bio-filtration system is set up based on the analysis of a typical and simple water treatment system. The system mainly consists of a fixed device and a planting filter. We elect ryegrass as the planting-filter, because it gets best sod, mechanic filtration and bio-filtration. Effects of static bio-filtration were studied in ryegrass. The results showed that the purification effects of ryegrass were significant and the removal rates of COD in wastewater reached 71.6%, 79.7%, 79.8%, 81.7%, 83.0%, and 81.0%, respectively. Near infrared spectra was used to analyze the water-quality, mainly dealing with chemical oxygen demand (COD). A set of 20 samples of domestic wastewater with different concentrations was taken from the Animal Institution of Zhejiang Agricultural Science Organization, and the partial least square (PLS) was used to develop predictive models. To validate these models, some samples were used. The values of SEP were 22 and 32, and values of r2 using the validation set of data were 0.9895, 0.9985 for COD of wastewater.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.