Abstract
Air quality monitoring was carried out at the three stations A, B and C of Line 1, Line 2 and Line 9 of Shenyang Subway station. CO2, formaldehyde, TVOC and PM2.5 were selected as pollutants. The results indicate that because the platform floor is far from the ground and there is almost no natural ventilation, the concentration of pollutants is higher than that of the station hall floor. The formaldehyde concentration of the newly built site A exceeded the standard by 37.1%. CFD was used for numerical simulation, and the section with human respiratory height Z=1.5m was selected as a typical section. The cloud map of temperature, velocity and concentration distribution of typical pollutants were analyzed to find out the areas where the concentration of pollutants exceeded the standard and analyze the reasons. The layout of tuyere which can improve the air quality in subway station is proposed, and the simulation and optimization research is carried out.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: IOP Conference Series: Earth and Environmental Science
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.