Abstract

We research ship 6 DOF inertial measurement method and displacement reconstruction form acceleration signal to establish the strap-down inertial navigation measurement system through sensors configuration technology. The inertial measurement system consists of three groups of vertically mounted angular rate and acceleration sensors. Through designing an FIR integration filter and studying the ship displacement signal reconstruction from the acceleration, the filter parameters design method and implementation way were determined. By means of the beam vibration to analog ship heave motion reconstructs linear displacement form acceleration signals. The root mean square error of the reconstructed line displacement is 0.004 mm, and the mean value of the displacement peak value is 5.92%, which is close to the design precision of the filter. The test shows that the measurement system and the FIR filter to achieve the predetermined precision with noise suppression.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.