Abstract
PurposeThe purpose of this paper is to study very fast transient overvoltages (VFTOs) in the secondary winding of air‐cored Tesla transformers and also study the resulting electric field stresses.Design/methodology/approachAn exhaustive model based on Multi‐conductor Transmission Lines (MTLs) theory has been used. The governing telegraphist's equations have been solved by Finite Difference Time Domain (FDTD) method.FindingsThe results demonstrated that there are some overvoltages at the end and middle turns that should be considered in insulation design. The magnitudes of these overvoltages are several times more than the steady state value of the corresponding turn which cause very high electric field stresses.Originality/valueThe paper describes results obtained from an original and innovative implementation of FDTD method in transmission line modelling and is applied properly to air‐cored pulse transformers.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: COMPEL - The international journal for computation and mathematics in electrical and electronic engineering
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.