Abstract

The measurement of 222Rn concentrations in indoor and outdoor air was carried out in certain locations of Mandya city, Karnataka, using the Solid State Nuclear Track Detectors (SSNTD) technique. The annual mean values of 222Rn in indoor and outdoor are found to be 20.5±1.4 and 9.0±0.5Bqm-3, respectively. The observed mean value of indoor radon concentration is found to be well within the world and the Indian average of 40 and 42Bqm-3, respectively. Outdoor radon concentrations have been measured in the vicinity of houses where yearlong radon measurements carried out using the SSNTD technique. The seasonal variation in the outdoor radon was studied and the average concentrations during summer, rainy and winter are 9.1, 6.9 and 12.9Bqm-3 respectively. Considering the possible factors such as house characteristics (Volume, Surface area of building material, Leakage area, etc.), indoor-outdoor temperature difference and outdoor radon concentration into account, the indoor radon levels were predicted using the existing model which is based on the mass balance equation. The results are systematically analysed and discussed. The predicted values are compared with the measured values.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.