Abstract

IntroductionThe purpose of this study was to evaluate the two-body wear resistances of natural enamel and four dental materials in vitro. MethodsThe testing machine was modified to form a type of pin-on-disk wear test apparatus. Four dental material specimens (Au-Pd alloy, Ag-Pd alloy, FiltekTMP60 and FiltekTMZ350 composite resins) and enamel were used as the pins, and a steatite ceramic grinding wheel was used as the abrasive counter face. The wear volume loss and the rigidity value was measured. The worn surface and the element analysis of the debris were analyzed. ResultThe wear volume loss of Au-Pd alloy and its steatite antagonists were the nearest to those of the dental enamel. SEM microphotographs showed that, the main wear mechanism of the dental materials was abrasive and adhesive wear. ConclusionsAu-Pd alloy had good wear resistance and was more suitable for dental applications than other three dental materials.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.