Abstract

This paper presents data on investigation of the pseudospark switch whose trigger unit uses a low-current auxiliary glow discharge with hollow cathode and hollow anode. The electrode system of this unit communicates with the main high-voltage gap of the switch due to the aperture in the flat part of one of the trigger electrodes. It is shown that when the electrode with the aperture plays of role of the hollow cathode of the auxiliary discharge, a low parasitic current through the aperture is provided by the ion flow. This ion current does not practically influence on the static breakdown voltage of the main gap. Applying the trigger pulse between the trigger electrodes leads to the pulsed trigger discharge with an enhanced current. At a negative polarity of the trigger pulse, the cavity with aperture turns out into the hollow anode so that the current is able to be intercepted through the aperture to the grounded cavity of the main gap. The plasma is generated in the cavity and the switch is triggered. With the proper selection of the geometry of the trigger electrodes, the delay time to trigger at a level of several tens of nanoseconds is achievable.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.