Abstract

To determine the volume and composition of clot within thrombosed hemodialysis access grafts. Clots were collected in 22 patients at surgical thrombectomy of polytetrafluoroethylene grafts. Histologic analysis was performed in 10 of these clots plus 21 randomly selected clots from the pathology archives. A small, firm piece of whitish thrombus ("arterial plug") was almost always recovered from the arterial limb of the graft. This plug had a concave surface and ranged from 5 mm to 3 cm in length. The remaining clot was soft, red thrombus. The mean weight of all clots was 3.4 g, and mean volume was 3.2 cm3. Average graft length was 42 cm. Histologically, the arterial plug had a characteristic appearance of densely compacted alternating layers of erythrocytes and fibrin. Clot volume in thrombosed dialysis grafts is much less (approximately equal to 25%) than would be expected if the graft were completely filled with thrombus, a finding of significance to mechanical thrombolytic techniques. Resistance of the arterial plug to pulse-spray thrombolysis is likely due to compaction.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.