Abstract

This study was initiated by the Belle detector upgrade plan including the replacement of the CsI(Tl) crystals in the endcaps by the pure CsI. Within this work five samples of pure CsI crystals were irradiated by the beam of 0.6 MeV γ -quanta. The absorbed dose accumulated in several runs reached 55 krad for two samples and 13 krad for three others. Four of these samples were found to satisfy the super B-factory conditions. The light output reduction for them does not exceed 15% at 13 krad of absorbed dose. One sample had poor radiation resistance.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.