Abstract

This paper describes the experimental studies carried out to determine 238Pu, 239/40Pu, 241Pu, 241Am, 242Cm and 244Cm in samples from nuclear power plants (mainly spent ion exchange resins and evaporator concentrates) using an organophosphorus compound immobilized on an inert support. These materials are commercially available under the name TRU Resin (for Transuranium Specific) from Eichrom Industries, Darien, IL. An attempt is made to develop a rapid, accurate method of analysis, with minimum waste generation. Standard solutions of Pu and Am and one sample of spent ion exchange resin that contains fission, activation products, Pu, Am and Cm were analyzed to study the separation factors and interferences in the measurement of Pu, Am and Cm isotopes.