Abstract

the effect of the interference between the diffuser vanes with the volute tongue was studied in this paper, based on the 3-d model of the residual heat removal pump and the numerical flow analysis platform developed with the commercial CFD software NUMECA. Results indicate that poor matching of the diffuser vanes and the volute may cause serious flow losses. The relative position between the diffuser vanes and the volute was optimized by numerical experiments. Final modifications indicate that the efficiency is increased by 6.4%.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.