Abstract
In this work, effluent wastewater treated by using cyclopentane-water Clathrate system to treat water contaminates with phenols at concentrations (300, 250, 200, 150, 100 and 50) ppm in order to investigate the capability of process performance. Clathrate or hydrate are strong crystal structures including water (host particles) and little particles (guest particles). The experiments were conducted at different cyclopentane-water volume ratios (1: 2 and 1: 4). The work was done in a 250 ml glass cell with an electric mixer at a constant speed of 280 cycles per minute. Phenol was highest removal percent at 300ppm at 1: 4volume ratio was (92.3%), while the lowest concentration at 50 ppm and 1: 2volume ratio was (55%). Yield and Enrich factor had the highest values at the lowest concentration 50ppm and 1:2 volume ratio were (85% and 2.42) respectively. The technique of the Clathrate proved that it has a high capacity in the separation and achieve high removal percentage compared to other methods at standard conditions when the pressure of 1 atmosphere and temperature higher than the degree of freezing water and less economic costs compared to other methods.
Published Version (Free)
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.