Abstract

In the energy industry, such as the gas field, precise measurement of wet gas is becoming increasingly crucial. Many studies have focused on the over-reading (OR) of throttle flowmeter in wet gas measurement. By using the dimensional analysis method, we proposed a precession Venturi and established a new OR correlation based on the gas Froude number, liquid-gas density ratio, and the Lockhart–Martinelli parameter. Experimental tests of air-water flow were conducted, and the relationships between differential pressure and OR with liquid volume fraction were investigated at various pressures and superficial gas velocities. The experimental results show that the uncertainty of gas flow rate measurement is in the range of 0.35%–0.56%, and 90.8% of the points are in the range of 0.35%–0.45%, with a relative error band of ±2.94% calculated by the OR correlation at a confidence probability of 95.5%.