Abstract

Superconducting reentrant cavities may be used in parametric transducers for resonant-mass gravitational wave detectors. When coupled to a spherical resonant antenna, transducers will monitor its mechanical quadrupolar modes, working as a mass-spring system. In this paper we will investigate the effect of the Niobium Nitride (NbN), produced through plasma immersion ion implantation (PIII), on the quality factor of reentrant Niobium (Nb) cavities. With the PIII surface treatment unloaded electrical Q-factors (Q0) of the order of 105 were obtained in cryogenic conditions. These results indicated a significant increase in the effect of superconductivity after the cavity surfaces have been heavily attacked by a concentrated acid mixture and after suffering successive PIII processes. Q0's ∼ 3.0 × 105 at 4.2 K are expected to be obtained using Nb RRR399 with a suitable surface treatment. These cavities, with high Q0, are already installed and being tested in the Gravitational Wave Detector Mario Schenberg. The experimental tests have been carried out at the laboratories of the National Institute for Space Research (INPE).

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.