Abstract

The issues were reviewed in assessing external electromagnetic fields’ effect on the parameters of an electrical power line probing system based on three-component ferroprobes for detecting active underground power cable lines during microtunnel construction using the thrust boring method (by tunneling shield) in densely populated urban areas. A study was conducted on the change in the topology of the energized cable magnetic field located in the external magnetic field area created by operating electrical equipment under the influence of an external electromagnetic field and a tunneling shield with installed magneto-sensitive detectors. Experimental studies of the probing system were made. Options have been proposed for compensating the inductance component of the external magnetic field during tunnel driving in urban development and industrial area conditions.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.