Abstract

This article contributes to deepening our understanding of the distribution of compression, tension, and shear stress in reinforced concrete mid-rise building shear walls. These L-shaped shear walls include openings that can account for up to 50% of the total wall area. To conduct this study, seismic performance analyses of the buildings were carried out using ABAQUS software on four distinct types of soils, subjecting the buildings to a high-intensity earthquake. Three wall thicknesses were considered: 15 cm, 20 cm, and 25 cm. The analysis results demonstrate that the use of thicker walls proved to be effective in reducing stresses, as expected, while also meeting the strength requirements. Furthermore, increasing the openings up to 30% in the shear walls allowed for a reduction in shear stress. However, it is important to note that the observed stresses varied depending on the type of soil and the percentage of openings in the walls.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.