Abstract

A study of the relationship of the raw wastewater BOD5:cBOD5 ratio was conducted at three wastewater treatment plants across the United States. Gwinnett County, Georgia; King County, Washington; and Littleton-Englewood, Colorado conducted a 3-month study using side-by-side samplers. The purpose of the study was to determine if cleaning wetted sampler parts routinely affected the ratio. One of the samplers was cleaned twice a week and the other was not cleaned. The results of the study show that cleaning the wetted parts of the sampler has a small but statistically insignificant impact on the BOD5:cBOD5 ratio. The study also showed a potential relationship of wastewater temperature to the BOD5:cBOD5 ratio, and also the possible influence of sampler type on raw wastewater characterization.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.