Steady-state superconducting tokamak (SST-1) is a medium size tokamak with superconducting magnetic field coils. Plasma facing components (PFC) of SST-1 are placed inside the vacuum vessel (VV) of the tokamak and are designed to be compatible for steady-state operation. The main consideration in the design of the PFC is the steady-state heat removal of upto 1 MW/m 2. In addition to remove high heat fluxes, the PFC are also designed to be compatible for baking at high temperature. Since it is difficult to calculate the radiation heat loads between PFC and VV in a 3-D irregular geometry, a simplified model of concentric cylinders has been chosen for the purpose of estimation of the power requirements and the thermal responses of PFC and VV during their bakeout phases. Thermal responses of the PFC and VV have been analysed and the analytical results have been compared with 2-D finite element analysis using ansys. The radiation losses between PFC and VV also have been evaluated on the actual model containing all PFC inside the VV.