Abstract
This study attempted to polish pure titanium test pieces electrolytically to mirror surface at the size of cast denture frames. Electrolytic polishing of pure titanium could be done on an area of 30 cm2 with a non-aqueous electrolyte. Small pure titanium plates could be polished electrolytically, but a uniformly smooth surface could not be obtained easily with large testpiece. The optimal electrolytic conditions were 30 V for 6 min at 25 degrees C using a solution consisting of 70 ml ethyl alcohol, 30 ml iso-propyl alcohol, 6 g aluminum chloride, and 25 g zinc chloride. The solution was safe and had less restriction of frequency of use.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Journal of the Japanese Society for Dental Materials and Devices
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.