Abstract
The pier longitudinal horizontal stiffness is the key technical parameter of rigid frame bridge and the continuous welded rail. Both the distribution of longitudinal force and the relative displacement between the beam and rail are rely on the longitudinal horizontal stiffness of the pier. This passage takes the symmetrical arrangement of different span rigid frame bridge in ballast track as an example to study the value of pier top longitudinal horizontal rigidity, using the finite element method. The analysis show that when the amplitude of rail temperature variation is less than 50 °C and the nominal temperature span within a certain range, the minimum value of pier longitudinal horizontal rigidity depends largely on the braking conditions. However, as the further increasing of the span, the pier longitudinal horizontal rigidity is restricted by the expansion conditions. Therefore, the small resistance fastening system should be taken into consideration. Especially, if the temperature of rail reaches above 50°C, laying rail expansion adjuster is needed in order to satisfy the requirement of the continuous welded rail temperature on bridge.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.