Abstract

Periodic flows downstream of centrifugal pump impeller in vaneless and vaned diffusers were measured by using a single hole yawmeter with a phase locked sampling method. The flows were also calculated by a inviscid flow analysis with the blade surface singularity method. The periodic variations in calculated static pressure with impeller rotating quantitatively agree well with measured ones. The flow behaviors in the vaned diffuser are discussed with measured and calculated results. The potential interaction between the impeller and diffuser blades appears more strongly than the impeller wake interaction. The appearance of static pressure fluctuations due to the impeller rotating in the fully vaned zone is different from that in the semi vaned zone of the diffuser. The existing of the peripheral surface of impeller outlet and the outlet edge of pressure surface of impeller blade causes the large pressure fluctuations in diffuser.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.