Abstract
In this paper, a new harmonic balance analysis approach based on the finite element method (HBFEM) is used to calculate the equivalent leakage reactance and the core loss in a magnetic frequency tripler. The HBFEM presented can be used to analyze harmonic magnetic field for time periodic magnetic field with B/spl sim/H curve described by any high order polynomial. Consequently, the current and flux density waveforms include many harmonic terms caused by saturation. An equivalent leakage reactance model of magnetic frequency tripler is presented based on the harmonic terms. The resulted harmonic-rich flux density waveforms are used to calculate core losses and equivalent leakage reactance. Simulation results are compared with experiment results and it is shown that the approach and model are correct and practical.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.