Abstract

SummaryTo verify the mathematical model of a scroll vacuum pump working process, an experimental unit for obtaining indicator diagrams was developed. The pump was modified to install gauges to measure quick‐varying pressures in the working chambers of the pump at different operating modes. The dependence of pressure on the rotation angle of the drive shaft at different inlet pressures is obtained. Comparison of experimental and calculated data shows convergence within 15 %.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.