Abstract
The first Radioactive Ion Beam Line in Lanzhou was a projectile fragment separator located in the HIRFL. The process of production and separation of radioactive ion beams can induce a strong and complex radiation field. The neutron dose equivalent rates were measured in four positions with a 70 MeV/u 40Ar18+ beam. The results were compared with that simulated by the FLUKA code. New shielding walls were installed to reduce the neutron background for spectroscopy measurement in the experimental terminal. In addition, the induced radioactivity of accelerator components and corresponding residual dose rates were analyzed for the radiation safety of accelerator workers. The airborne radioactivity as well as occupational exposure due to immersion in and inhalation of activated air were also estimated. This work aims to provide a valuable experience for the radiation study in the future fragment separator HFRS at HIAF.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.