Abstract

A kind of fusion dianostics based on proton recoil method and magnetic analyzing technology is introduced. It can be used for the accurate diagnoses of plama tempreture, fuel density and neutron yield. A prototype is designed, using a high-powered Nd-Fe-B permanent dipole for magnetic analyzer, and proton position distribution in the focal plane is measured by CR-39 trajectory detector or PIN detector. The system is calibrated with a 239 Pu source, and a corresponding particle transport simulation program is worked out. The performance of the spectrometer is investigated with the Monte Carlo simulation, and neutron experiments are taken on the K-400 accelerator.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.