Abstract

To evaluate the feasibility of low radiation exposure and low contrast medium volume for coronary CT angiography with High- pitch spiral acquisition mode of dual source CT. 135 patients whose BMI <23 kg/m² and heart rates <65 bpm selected from 291 patients diagnosed of suspected CHD at our institution from September 2013 to February 2014 were randomly divided into 3 groups before CCTA, and there were 45 patients in each group. 80 kV , Iodixanol (320 mgI/ml) and sinogram affirmed iterative reconstruction (SAFIRE) were used in A group. 80 kV , Iopamidol (370 mgI/ml) and SAFIRE were used in B group. 100 kV, Iodixanol and filtered back projection (FBP) were used in C group. Two radiologists assessed image quality with 5-piont scale subjectively and double-blind. Independent-Sample Test was used to analyze statistical significance of image quality including signal to noise ratio(SNR) and contrast to noise ratio (CNR) between A and B group or between A and C group. At the same time, Contrast medium dose statistical significance between A and B group and mean effective Radiation dose (ED)statistical significance between A and C were analyzed by the same way. There were no significant difference of image quality including SNR and CNR of aortic root (AO), left main coronary artery (LM), left anterior descending artery (LAD), circumflex coronary artery (CX) and right coronary artery (RCA) Between A and B group (P = non-significant for all comparison), whereas Iodine in taken of A group decreased 14% (17 600 mg vs 20 350 mg). There were no significant difference of image quality including SNR and CNR of AO, LM, LAD, CX and RCA Between A and C group (P = non-significant for all comparison), whereas mean ED of A group decreased 50% (0.41 ± 0.05 mSv vs 0.79 ± 0.15 mSv). The double low dose application which use High-pitch spiral mode, 80 kV, SAFIRE, and Iodixanol (320 mgI/ml) can be used in those patients whose BMI <23 kg/m² and heart rates <65 bpm to reduce the burden of radiation and contrast medium significantly, without compromising the image quality.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.