In this paper, the reliability issue of the LED lamp in high temperature and moisture condition was investigated. Thermal stress and hygroscopic stress in the LED package were obtained by coupled-field analysis using Finite element analysis (FEA). The results demonstrate that the temperature of the module can reach saturation in tens of seconds while the moisture field needs longer to reach balance. 85°C/85RH can reach the same distribution of relative humidity with 65°C/65RH, but the time spent is half. So temperature is the important factor to affect the humidity distribution. The moisture concentration is better than the relative humidity response to the material moisture level. So we made further research on hygroscopic stress. Both the thermal stress and hygroscopic stress contributed to the delaminations in LED packages.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.