Abstract

AbstractThis work is devoted to the diagnostics of interaction between hydrogen and argon with the surface of SiO2 glass walls. For diagnostics of the interaction, special high‐frequency electrodeless light sources were prepared, filled with pure argon of 1 Torr or argon‐hydrogen of total pressure of 1 Torr (Ar/H2 mixing ratio is 9:1). Besides the mostly used spherical and cylindrical lamps, dumbbell type lamps have also been investigated. The spectroscopic and AFM measurements showed that in comparison with pure argon plasma, the argon‐hydrogen plasma causes non‐uniform changes of the SiO2 surface. For these modifications active OH are primarily responsible molecules, created in the reactions of hydrogen molecules with oxygen molecules, adsorbed from the walls.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call