Abstract

This paper presents a systematic study of the use of formic acid vapor fluxless soldering with eutectic Pb/Sn solder. The study focused on the solder joint self-aligning process and the final alignment accuracy. The main effect considered was the formic acid vapor concentration. In addition, other effects of solder joint height and background vibration were studied. The self-alignment characteristics of the fluxless soldering process was as good as those using liquid flux at 220/spl deg/C. 2 /spl mu/m alignment accuracy could be achieved within 10 s. The most important parameter was the formic acid vapor concentration in the reflow chamber. The effective concentration window was found to be greater than 0.7% in volume.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.