Abstract
Critical heat flux (CHF) of Subcooled Flow Boiling with water in a tube was investigated from the viewpoint of mechanistic models. The Weisman-Pei bubble crowding model was selected to predict CHF in a short tube and in a tube with an internal twisted tape under nonuniform heating conditions, Based on the results of bubble behavior observation and preliminary analysis. The original Weisman-Pei model was modified in order to explain the physical phenomena of CHF. The modified model predicted well CHF in a smooth tube including the very short tube and the tube with an internal twisted tape under uniform and nonuniform heating conditions.