Abstract
AbstractInterference of alternative current (AC) on corrosion of X65 steel was investigated in soil. It was observed that the unfavorable effect of interfering AC was able to be effectively inhibited by increasing the direct current density of the cathodic protection (CP) system. A clear correlation was established between the CP current density and the tolerable AC current density. This led to a new criterion for assuring the effectiveness of CP of buried pipelines being interfered with AC. Field experimental results on a buried pipeline running below a 500 kV transmission line showed that the criterion could satisfactorily predict the risk of AC interfering on the CP system.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.