Abstract
This paper presents the study of common-mode (CM) voltage measurements for IEC 62684 regulatory. Due to the digitization error caused by the limited vertical bit number of the analog-to-digital converter (ADC) in oscilloscopes, the CM voltage spectrum measurement of the flyback converter with ac source occurs significant inaccuracy. In order to avoid the digitization error, the CM voltage measurement of the flyback converter with dc source is proposed in this paper. The simplified equivalent circuits of the flyback converter with ac and dc input sources are derived to calculate the ratio of their CM voltages. With 64-bit circuit simulation software SIMPLIS, the digitization error can be significantly reduced to have high-resolution measurements for the verification of the calculated CM voltage ratio. The ratio of the calculated CM voltages can be used to modify the measurement result with dc source to obtain the equivalent result with ac source.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.