ABSTRACTIn view of benefits expected from the employment of membranes for particle control in fusion devices and for separation of hydrogen from its mixtures with hydrocarbons, the behavior of a Pd sample is investigated in a plasma-membrane device with a graphite target. The permeation of hydrogen through a 0.2 mm-thick Pd membrane with clean surfaces was found to be limited by the bulk diffusion. An incident flux of hydrocarbon radicals (approx. 2×1012 cm−2s−1) in hydrogen plasma forms no carbon layer on the Pd surface. Applying of a negative bias to the target gives rise to target sputtering, and to the deposition of carbon onto the membrane surface. The formation of carbon layer results in a decrease of the absorption probabilities of both H2 molecules and H atoms. The effect of the deposition of carbon is found to depend non-monotonically on membrane temperature.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.