Abstract

This article is the first part of a study which analyzes the performance and internal flow of an ESP when handling oil-water flow, focusing on the characterization of the two-phase flow/emulsions observed and their influence on the ESP's global performance. The testing facility consisted of a four-stage ESP located in a closed-loop arrangement. W/O emulsions are formed at high oil fractions, due to the presence of surface-active compounds and small droplet sizes. At the inversion, an increase in the viscosity and shear-thinning characteristics of the emulsion is noticed. At higher water cuts, the emulsion's microscopic structure is lost, transitioning to a dispersed two-phase flow. The head rise increased noticeably at the inversion point thanks to the shear-thinning trend observed. The ESP's performance improves at higher water fractions due to lower viscosities with a shear-thinning nature. As the non-Newtonian behavior is lost, higher water cuts do not affect the pump's operation.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.