Inductance type displacement transducer is generally of two types LVDT type and simple self inductance type. Both these types may suffer from various defects such as non-linear operation near the end and shortening of linear range etc. In the present paper a modified differential inductance type linear displacement transducer has been developed. In this technique, the defects of the other inductive displacement transducers have been eliminated. The theory of operation of the proposed transducer has been described. The developed transducer has been functionally tested and experimental results are reported in the paper. A very good linear characteristic of the transducer with good repeatability has been observed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.