Abstract

The tradition RC building slab system is very rigid so the vibration and the will induce large noise often creates puzzle of the user. The slab vibration also will reduce the production fine proportion for high tech factory. So we must to enhance the RC slab energy absorbing capacity to reduce RC floor vibration. The rubber material has very good elasticity and energy absorbing capacity so is widely applied in many daily items. But the easy consuming characteristic will increase the waste process problem. If we can apply the high elasticity property in recycle rubber to RC slab so we can reduce the waste pollution and slab vibration behavior in the same time. The complex RC slab real behavior must be measure from test result. In this paper we want to get the dynamic behavior by pedestrian loading for rubber concrete RC slab by laboratory test. By the test results we can found the 5% rubber concrete will concentration to 7.2 Hz.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.