Abstract

In this paper, sensor responses with only metal electrode as Au, Cr, Ti and more with LB film were described. LB film material was the Dioctadecyldimethylammonium bromide combined by PVSK as an underlayer. To detect five basic taste substances, sensor parameters were defined as maximum voltage change and response time. Response time for sourness and umami with Ti and Cr evaporated metal electrode was larger than that of usual Au electrode. LB film effect was finally found to increase response time for five basic taste materials.