Abstract
A sinogram is directly recorded onto an imaging plate for neutron tomography, which has excellent capability to detect neutrons. A sinogram-recording-system and outline of the data processing are explained briefly. A tomogram of a test object is reconstructed and shown as the preliminary result. The linearity of CT values was experimentally confirmed up to 1.6 cm −1 of effective total macroscopic cross section, but about 10% lower CT value was observed at 2.7 cm −1. The linearity limitation and statistical character of CT values are discussed with regard to the dynamic range of the system as well as the effect of background components.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.