We compared axillary and rectal temperatures in 216 patients to assess the reliability of axillary temperature for determining fever in children under 14 years of age. Beyond the neonatal period, the mean rectal temperature was significantly higher than the axillary temperature. The sensitivity of axillary temperature in detecting fever was 87.5% among neonates but only 46% among older children. Axillary temperature correlated well with rectal temperature in neonates but not older children. There was no direct mathematical relationship between axillary and rectal temperature. Axillary temperature should be taken in neonates as it is less hazardous; rectal temperature should be used beyond this age.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.