Abstract

R&D studies on the performance as well as on the gas properties of the microMEGAS-based time projection chamber with standard readout were carried out in June 2005 using 4 GeV/c pion beam in a magnetic field from 0 to 1 T at the proton synchrotron beam line at KEK, Japan. Analysis of the electron drift velocity, diffusion constant and point resolution of padrow measurement for MicroMEGAS TPC filled with 95% argon and 5% isobutane gas are presented. The underlying physical mechanism which determines the optimal TPC performance are briefly discussed. Preliminary measurements of gas properties and spatial resolution in close agreement with the analytical calculation and MAGBOLTZ simulation are summarized and presented in this paper.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.