Abstract

Titanium activation foils for neutron studies were exposed inside the JET tokamak vessel during the entire 15 months long experimental campaign with deuterium fuelling. Afterwards, it was found that the structure of some foils was only slightly affected, while others were totally or partly disintegrated into dust: flakes and powder. The analyses indicated that defects produced in materials by cutting during the sample preparation eventually lead to the degradation of the titanium crystal structure upon the exposure in JET to neutral particles including hydrogen. In some cases, a passive oxide layer on the foil surface effectively prevented the access of hydrogen, and - by this - protected the metal against partial or complete transformation into the titanium hydride powder.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.