Abstract

Transformation of mercury compounds in combustion flue gas and overall mercury mass balance in a typical bituminous coal-fired power plant were studied. Upon decreasing temperature and interaction with flue gas components, oxidized mercury increased across an electrostatic precipitator. A major fraction of particulate mercury was removed in the electrostatic precipitator, and oxidized mercury was removed in wet flue gas desulfurization. Hg was mainly speciated into elemental form in the stack emission. The measurement of mercury in a real facility and equilibrium calculation showed that coal composition, operating conditions, and flue gas components were the major factors affecting mercury emission and speciation. A reliable overall Hg mass balance was obtained from the field measurement. Mercury mainly entered from coal, and lime/limestone feeding was distributed in electrostatic precipitator fly ash (57.6−64.3%), gypsum (4.5 −12.9%), effluents (0.5−1.9%), and stack emission (15.2−27.0%). Further, the ma...

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.