Abstract

AbstractPerhydroxycucurbit[6]uril {(HO)12CB[6]} has been used successfully as a stationary phase for packed column gas chromatography for the first time. Perhydroxycucurbit[6]uril stationary phase (PSP) exhibited wide operational temperature, outstanding thermostability and good selectivities to various organic compounds, such as alkanes, aromatic hydrocarbons, alcohols, esters, ketones, amines, etc. It was also found that some positional isomers, such as disubstituted benzenes could be well separated on this column. PSP has excel1ent separation abilities to some complicate samples, for example, commercial toilet water. Some mechanism of the new packing for GC‐separation was preliminarily discussed. It was observed that the partial inclusion complexation of PSP with analytes could improve separation selectivity and column efficiency, instead of complete inclusion. Moreover, PSP exhibited low baseline shift even at dramatically programmed temperature for complicate samples covering a wide boiling point range so as to fast assay.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.