Abstract

A feedback control system using an ion beam as a remote suppressor has been previously shown to be very effective in suppressing plasma instabilities in the Columbia Linear Machine [G. A. Navratil et al., Plasma Phys. 24, 184 (1982)]. The first experimental measurements for the effect of this feedback system on anomalous particle transport, as determined from the cross-correlation of density and potential fluctuations is presented. It is shown that feedback reduces transport due to a rotational E×B mode by up to a factor of 3 in this experiment. Also, it was found that particle transport scales linearly with fluctuation amplitude and feedback control does not alter this scaling. Last, the experimentally observed scaling of particle transport does not agree with any theoretical predictions.