Timing and amplitude properties of a prototype scintillator TOF counter at an external target facility are studied with a cosmic rays test. The dependence of signal pulse height and time resolution on the coordinate along the scintillator TOF counter is investigated with two different discriminators. A time resolution of 165 ps can be achieved at the center of the counter with a constant fraction discriminator. Time resolution better than 150 ps is obtained at the center with a leading edge discriminator after time walk correction is applied for off-line analysis.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.