Abstract

Measurement of radioactivity in cosmetics such as face powders and eye liner (kohl) has not been reported so far. Herein gamma ray spectrometry and CR-39 solid state nuclear track detector have been used to investigate six cosmetics of different brands. The results have demonstrate that the average values of specific activities of 238U, 232Th and 40K were 12.66±2.96, 14.58±8.83 and 269±120 Bqkg−1, respectively. Also the average radon exhalation rate was 0.21±0.04 Bqm−2h−1. The calculated radium-equivalents were lower than recommended value (370 Bqkg−1). The absorbed dose rates due to the natural radioactivity of the investigated samples ranged from 6.83±2.6 to 99.5±51 nGyh−1. Also, X-ray fluorescence spectrometry studies showed that the concentrations of the heavy Mo, Sr, Pb, Zn, Cu, Ni, Fe, Mn, Rb, As, Zr and Cr were 4±0.96, 26.93±12.24, 110135±109973, 672.98±433, 1001±722, 318±145, 3847±790, 60±25, 24.71±13, 9002±4210, 24.71±18 and 153±72 ppm, respectively.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.