Abstract
Summary Tellurite was titrated amperometrically with permanganate in presence of 0.05–0.1 N NaOH and in presence or absence of telluric acid. At−0.8 and−1 V reversed L-shaped curves were obtained; at−1.4 V, the curves were V-shaped. The results agreed with those of potentiometric titrations.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.