According to a intake tower of spillway tunnel established the intake tower structure—water—foundation 3-D finite element model for seismic analysis, by the response spectrum method in original design seismic parameters and new parameters of the project on horizontal and vertical dynamic response of the intake tower. The results shown that the structure of maximum dynamic stress concentration appeared near the junction of the tower with backfill concrete, where the weak parts of seismic, used the new seismic parameters calculated show greater damage on the tower, but couldn’t overturn, meet the seismic design requirements.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.