Abstract
The flue gas desulphurization plants in the brown coalpower stations of RWE Energie AG operate in accordance with the limestone process. 37 scrubbers with a total of 210 000 m2 steel surface are lined with a soft rubberized coating based on chloroprene base, butyl rubber/chloroprene and butyl rubber. The 110 000 m2 surface of the outlet ducts is coated with synthetic resin materials based on polyester/glass flake and vinylester/glass flake spray-coatings. This paper reports on the erroneous modifications which have already occurred during a short operating period. With metallographic methods combined with light-optical and scanning electron microscopy (SEM) as well as X-ray diffraction analysis the structure of the material in the as-received condition is characterized and compared with the changes resulting from the stress due to the exposure during operation.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.